Click Settings….
The dialog Settings for the corresponding discipline opens.
-
Activate the option Output Manufacturer-neutral Material.
- In the discipline Potable Water, the option is located on the Calculation Parameters tab.
- In the disciplines Waste water and Roof Drainage, the option is located on the General tab.
- In the discipline Ventilation, the option is located under Calculation Settings.
-
Close the Settings by clicking OK.
-
Perform a calculation again and confirm the calculation by clicking OK.
-
Click Output….
The Output dialog opens.
-
Select the print item Parts list under Material and set additional output options if needed.
-
Click
- Print to start the printout.
- Preview to display the parts list in a preview window.
Manufacturer components are listed under neutral components in the parts list, and manufacturer names and items numbers are not visible.