This dialog box lists all mounting configurations, as well as all connection sets sold by the manufacturer and the number of items included in each connection set, which are also listed in the bill of materials. The list of included items can be edited and, if necessary, supplemented with additional items from the manufacturer's data set, provided that the data set allows for this.

You are here:

Project TabDiscipline HeatingAnalyse TabComponentsAdditional MaterialSelect ManufacturerRadiator Connections

Dialog Radiator Connections LINEAR Solutions for Autodesk Revit

Element

Meaning

Section for defining the position of the connection in the radiator connections dialog

Position of Connection

The connection position can be changed and then might make different connectors necessary. Left-click to set the connection position for the flow, and right-click to set it for the return.

Radiator Connection

The connection of the selected radiator is shown. The radiator connection is determined using the function Radiator Connection ....

Pipe System

Select a pipe system that contains the desired connecting set. Here you can select from all the piping systems offered by the manufacturer selected in the Additional Material dialog box.

Connecting Set

If the selected manufacturer pipe material contains more than one set, you can select the one desired here.

Termination Set

Enabled: Bends are output in the parts list for the connection to the connecting pipe.

Disabled: T-pieces are output in the parts list for the connection to the connecting pipe.

Set contains Fittings

Enabled: The number of fittings for the parts list corresponds with the number of detected fittings from the constructed pipe network and with those fittings coming from connecting sets, if selected.

Disabled: Not relevant for Revit. For 2D-drawings, this checkbox can be deactivated. Per radiator, the connecting material has automatically additional fittings added for the parts list.

Qty.

Change the number of items from the selected connection set or from supplementary material.

Item No.

Item Number

Item Text

The texts are from the manufacturers data sets.

A

Alternative position: If this item is to be treated as alternative position, activate this field.

Add

Add supplementary material to the connection set from the manufacturers catalog. The button opens the dialog Item Selection, in which more items can be selected. Additional items are part of the parts list.

Delete

Deletes supplementary material from the table. Items that are part of the default connection set can not be deleted.