A building unit (BU) is a part of a building used by a party, in which the party can individually control the heat supply. A room cannot be part of two building units. The settings for the building unit are not relevant in the heat load for Denmark.
A ventilation zone (VZ) consists of rooms that have a direct or indirect air connection due to their dimensioning. According to the dimensioning, there is no air exchange between ventilation zones. Therefore, one room cannot be part of two ventilation zones.
In the building data, you set globally at which structural level you want to define building units and ventilation zones. Depending on this setting, you have the option of excluding a building part from being considered as a building unit at the level set. This is useful, for example, for staircases or shared basements.
| Building | BU | VZ | Notes |
|---|---|---|---|
| One-family house | Project | Project | |
| Multi family house, ventilation per apartment | Apartment | Apartment | Staircase no part of a BU |
| Multi family house: Apartment over several storeys | Apartment | Apartment | Numbers and names of the connected apartment have to be identical. |
| Multi family house, ventilation central | Apartment | Project | Staircase no part of a BU |
| Shopping Mall | Area | Storey, project | Optional Atrium own area |
| Shopping mall, two ventilation systems per storey for BU | Area | Storey | Division into building parts, create same storeys per building part |
| Industrial building (hall and offices own VZ) | Project | Building Part | Create different storeys per building part |
| Office building (one company) | Project | Storey, project | |
| Hospital | Project | Area |