Details on Settings (Project Level- Waste Water)
Information about the Settings tab of the scheme generator for the Waste Water trade.
In the Settings you can make general default settings for the scheme construction and the pipe network calculation. The settings apply to the whole project. The Settings are only visible when you are in the Building structure at storey or project level.
You are here:
Connection to Waste Water Pipe Run
with Single Branch, with Double Branch, automatically (if possible without chamfer), without Chamfer
Determine whether the connections to the waste water pipe run are designed as single or double branches. With the Automatic Setting (if possible without chamfer), the connection of collector pipes or single connection pipes to the down pipe is carried out without chamfer if possible, i.e. with a 90° angle.
| Connection Type | Construction in the generated scheme |
|---|---|
| with Single Branch | ![]() |
| with Double Branch | ![]() |
| automatically (if possible without chamfer) | ![]() |
Sewer Junction
under Floor Slab, under Basement Ceiling
Determines whether the sewer junction is placed under the bottom plate or under the ceiling of the lowest storey.
| Type of Sewer Junction | Display in Pipe Run Scheme |
|---|---|
| underneath Floor Slab | ![]() |
| under Basement Ceiling | ![]() |
Material
Pipe Material ...: Opens the Pipe Tables dialog where you can specify the material for the entire pipe network.
Pipe Run Material...: Opens the Pipe Run Material dialog, where you can specify different pipe run material for the pipe run.
Basement Material...: Opens the Basement Material... dialog, where you can specify a different pipe material for the pipes in the basement.
Valves: Opens the Valves dialog where you can compile a valve preselection for the pipe network calculation.
Configuration...: Opens the Settings dialog, in which presettings for the pipe network calculation can be made.
Manufacturer Selection...: Opens the Manufacturer Selection dialog, in which you select a manufacturer to make its product data set available in the Pipe Tables dialog.
Plot
Distance between Consumers
Sets the clear distance between the consumers in the scheme.
Text Height
Sets the text height of the label.
Show Sheet Format
Enabled: The scheme is given a sheet frame including title block.
Label Consumer
Enabled: The consumers are labeled with the flow path number, mass flow, rate, capacity, and valve setting. The consumers are labeled only when the scheme is generated as a labeled plan. If you have selected w/o Labeling, consumers are also not labeled.
Height above Floor
Sets the height of the label above the floor in the scheme.