Details on “Assign Item Numbers"
Information on the dialog Assign Item Numbers.
Allows you to customize the settings for assigning position numbers. You can start assigning item numbers for all components from the dialog. After closing the dialog, the item numbers are no longer displayed in the drawing. However, they are still internally assigned to the components and available for labeling.
You are here:

Maintain Existing Numbers
Enabled: When selecting parts with existing item numbers, the previously assigned item numbers are maintained.
Disabled: When selecting components with existing item numbers, the previously assigned item numbers are overwritten with the number to be assigned next in the numbering process.
Use Blanks in Numbering
Existing numbering of components may have gaps, e.g. due to a preceding numbering with an increment greater than 1 or if components have been deleted. Start this function before you start the numbering again.
Enabled: During numbering, existing gaps are filled first before numbering continues at the end of the already existing numbering.
Disabled: Gaps in the numbering are not taken into account and the numbering is continued at the end of the already existing numbering.
Same components get same number
Identical components are, for example, valves or bends of the same type with the same technical values.
Disabled: Identical components are not given the same item number in the numbering. The next number that is currently available in the numbering process is assigned.
Components of one section get same No.
Enabled: All parts that are selected during numbering receive the same number and are combined into one section. After ending the assignment of a section (ESC key), restart the numbering to assign item numbers to components of another section.
Group (Number Range)
Enables the use of up to three labeling groups (Item Lists). Each labeling group has its own number range, so that in each of the 3 groups the numbering can start at 1, for example, and equal numbers can be assigned.
The labeler to be used for the item number labeling varies depending on the selected item list, as each item list uses a different parameter.
| Position List | Labels in the "Label components <" area | Used Parameter: Parameter ID |
|---|---|---|
| Position List | Position | Item Number (range A): <<|LIN_POSITION_NUMBER_A|>> |
| Position List 2 | Position2 | Item Number (range B): <<|LIN_POSITION_NUMBER_B|>> |
| Position List 3 | Position3 | Item Number (range C): <<|LIN_POSITION_NUMBER_C|>> |
Main Numbers
Prefix (e.g. abbrev. for system), Postfix
Enter the text that is to be placed before or after after each item number.
Next number to be assigned
Displays the number that will be assigned next and allows you to specify with which number is used to begin or continue numbering.
Increment
Use 10, for example, if you want to number components in steps of 10.
Sub Numbers
Allows you to use alphabetical or numerical sub-numbers. You can specify the main number used in numbering in the Next number to be assigned field.
Label directly
Enabled: When assigning numbers, the components are directly labeled as well, provided that the component supplies data for the labeler. Make sure that the corresponding label is selected in the Label Components < area.
The label to be used for the item number labeling varies depending on the selected item list, as each item list uses a different parameter.
| Position List | Label to be used | Used Parameter: Parameter ID |
|---|---|---|
| Position List | Position | Item Number (range A): <<|LIN_POSITION_NUMBER_A|>> |
| Position List 2 | Position2 | Item Number (range B): <<|LIN_POSITION_NUMBER_B|>> |
| Position List 3 | Position3 | Item Number (range C): <<|LIN_POSITION_NUMBER_C|>> |
Further Options...
Opens the following menu with various options for resetting item numbers:

Reset all with prefix “(...)”
Allows to remove all position numbers with a specific prefix. By default, the last used prefix is offered. If you want to remove the numbers of another prefix, select the corresponding prefix from the Prefix (e.g. System Abbrev.) drop-down list in the Main Numbers area. After executing the command, the numbers remain visible until a new numbering is started or a numbering is continued or the dialog is closed.
Reset Labeling Group (...)
Allows you to remove item numbers of entire labeling groups. By default, the last used labeling group is proposed for reset. If you want to remove the numbers of another labeling group, select the corresponding Item List in the Group (Number Range) area. After executing the command, the numbers remain visible until a new numbering is started or a numbering is continued or the dialog is closed.
Reset with object selection
Allows you to remove item numbers by selecting objects in the drawing.
Start
| Selection mode | Description |
|---|---|
| S (Single) | Click on a single component to select it. |
| P (Path) | Select a start component and then an end component to select these parts and all the parts in between on the path. |
| N (Network) | Select a start component and then a component in the direction of the network side you want to mark. This allows you to select pipe and duct networks from a component to the start or end of the network. The additional option search in all directions allows you to select the entire network after selecting a component. |
Close