Detail on Assistant Fresh Water and Dwelling Stations
Information on the dialog Assistant Fresh water and Heat Interface Units.
With the assistant for fresh water and heat interface units, you can dimension manufacturer models and insert it into the project. Furthermore, you can edit the configuration of stations that have already been drawn in. The prerequisite for using the assistant is the installation of a suitable manufacturer data set.
You are here:
Applies to: Heating, Potable water.

Manufacturer, Product group, Product range
Select manufacturer, product group and version of the product. If you select a model including water meter calorimeter, the Calorimeter and Water meter sections are displayed.
Calorimeter, Water meter
Enter Nominal volume flow rate and Pressure loss for each of the meters if the product contains a heat quantity and water meter.
Selection Accessory material ...
Opens a dialog in which you can select accessory material that the manufacturer provides for this product. The accessory material is included in the parts lists.
Potable Water...
Opens the Requirement Potable Water dialog, in which you can enter the potable water heating requirements for the heat interface unit.
Floor heating ...
Opens the Requirement Floor heating dialog, in which you can enter the floor heating requirements for the heat interface unit.
Product illustration
Shows a preview of the selected product. Some manufacturer offer a link to their homepage where you can get more information about the products.
Design capacity, Error messages, Notes
After successful dimensioning of the heat interface unit the dimensioning data are displayed below the product illustration and the Draw < button is activated. If the selected product does not match the entered requirement for potable water heating and floor heating, an error message is displayed in red, below the product illustration and the heat interface unit cannot be drawn. If the errors are corrected, the design data is displayed instead of the error message. Depending on the product, additional information texts are displayed below the design data or error message.
Technical data and Data sheet ...
If the manufacturer provides technical data and a data sheet in the data set, you can view these here.
Draw <
After clicking Draw < the heat interface unit is attached to the mouse pointer and you can place it in the drawing with the settings you have made.
Get <
Clicking a dwelling station loads all data of this dwelling station including the relevant data of a possibly connected radiant heating systems into the assistant’s dialog.
Assign <
Transfers the data currently set in the dialog to all desired heat interface units and connected heating systems. After selecting the corresponding heat interface units in the drawing and confirming with Enter, you can select in a query whether only the data is assigned or whether the model is also changed at the same time. When swapping models, the station is replaced from origin to origin.
If no symbol or 3D model is available for the heat interface unit set in the dialog, only the new data will be written to the selected stations without a query.
If the current configuration of the heat interface unit in the dialog is incorrect, the Assign < button is disabled.