Details on Component Data for Slide Valves

Information on the component data dialog for Slide valves.

You are here:

Project tabDisciplineAnalyse tabComponentsTechnical dataComponent

Name

Specifies the name of the component. You can modify the name. Clicking restores the default setting.

Calculation

Nominal diameter: You can either select a fixed nominal diameter, or the calculation is determined with the selection dimensioning. After the calculation, the calculated values will be displayed below the field under Current.

Zeta: You can enter an additional pressure loss as zeta value. When calculating according to work sheet G11 of the ÖVGW standard, the Zeta-value will be determined by the program for all components.

Connections

The connection type can be selected from the drop-down list. When choosing Standard, the connection is set by the program.