Details on "Edit Pipe Sections"
Information about the Edit Pipe Section dialog in the Rohrnetzberechnung Heizung, the Rohrnetzberechnung Kälte and the Rohrnetzberechnung Quartiersnetze.
The dialog allows you to influence the calculation by individually adjusting calculated data or max. values for pipe sections. Results in the calculation dialog that change due to adjustments in the Edit Pipe Sections dialog are displayed in bold in the calculation dialog.
You are here:
Applies to Heating, Cooling and District Networks.

Settings
Length, Height Difference
The values are taken from the drawing. You can change the values here if necessary. Clicking
resets the values to the drawn dimensions.
Pipe Bends 90°, Pipe Bends 45°
designed: Shows the amount of constructed bends in this pipe section.
additional: Enter the amount of bends that are to be given out as additional material in the material list.
Constant Pressure Loss
Enter an additional pressure loss for this pipe/duct section or for this trench section.
Ambient Temperature
The ambient temperature is taken from the Settings and can be adjusted for each pipe/duct or trench section. Clicking
resets the value to the value from the Settings.
Maximum Values (Local)
R-Value
If you want to assign a different maximum pipe friction pressure loss to this pipe/duct section or trench section, enter the value here. When entering 0, the maximum value from the global settings of the Basic Conditions dialog is used.
Velocity
If you want to assign a different maximum velocity to this pipe/duct or trench section, enter the value here. When entering 0, the maximum value from the global settings of the Basic Conditions dialog is used.
Diversity
Enter the diversity for this pipe/duct or trench section. The diversity is automatically assigned to the supply and return pipes.
Reset
Resets all entries to the designed value off the drawing.